{"id":13203,"date":"2025-12-05T15:18:00","date_gmt":"2025-12-05T15:18:00","guid":{"rendered":"https:\/\/ipsenglobal.com\/?post_type=knowledge-center&#038;p=13203"},"modified":"2026-03-11T16:32:12","modified_gmt":"2026-03-11T16:32:12","slug":"vacuum-furnace-thermocouples","status":"publish","type":"knowledge-center","link":"https:\/\/ipsenglobal.com\/de\/knowledge-center\/vacuum-furnace-thermocouples\/","title":{"rendered":"Vakuumofen-Thermoelemente"},"content":{"rendered":"<h4 class=\"wp-block-heading\">Von Chuck Reed, leitender Ipsen-Kundendienst-Verkaufsspezialist<\/h4>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Thermoelemente spielen eine entscheidende Rolle bei der W\u00e4rmebehandlung, da sie genaue Temperaturdaten liefern, die einen sicheren und gleichm\u00e4\u00dfigen Betrieb der Ofensysteme gew\u00e4hrleisten.<\/strong> Sie sind f\u00fcr extreme Bedingungen ausgelegt und werden zur Erkennung von Temperaturen au\u00dferhalb des zul\u00e4ssigen Bereichs, zur \u00dcberpr\u00fcfung der Gleichm\u00e4\u00dfigkeit von \u00d6fen und zur \u00dcberwachung der Temperaturen w\u00e4hrend eines Produktionslaufs eingesetzt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thermoelemente funktionieren, indem zwei unterschiedliche Metalldr\u00e4hte (z. B. Nickel und Kupfer oder Platin und Rhodium) zu einer Messstelle verbunden werden. Wenn diese Stelle W\u00e4rme ausgesetzt wird, erzeugt sie eine geringe Spannung \u2013 eine Reaktion, die als Seebeck-Effekt bekannt ist. Die Beziehung zwischen Temperatur und dieser Spannungsabgabe ist f\u00fcr jeden Thermoelementtyp genau definiert, sodass Ofensteuerungen die Temperatur innerhalb eines bestimmten Bereichs interpretieren k\u00f6nnen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">W\u00e4hrend Thermoelemente sowohl f\u00fcr sehr hohe als auch f\u00fcr sehr niedrige Temperaturen verwendet werden k\u00f6nnen, hat jeder Thermoelementtyp je nach den verwendeten Materialien seinen eigenen nutzbaren Temperaturbereich und seine eigene Empfindlichkeit.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In einem <a href=\"https:\/\/ipsenglobal.com\/de\/vacuum-furnaces\/\" type=\"page\" id=\"3431\" target=\"_blank\" rel=\"noreferrer noopener\">Vakuumofen<\/a>, Einige Thermoelemente werden speziell dazu verwendet, Informationen an die Temperaturregler zu liefern, Informationen, die anzeigen, wann Elemente w\u00e4hrend eines Prozesses ein- oder ausgeschaltet werden m\u00fcssen. Andere Thermoelemente werden entweder f\u00fcr einen einzelnen Produktionslauf oder eine kleine Anzahl von L\u00e4ufen verwendet, um sicherzustellen, dass die Rezepte die richtigen Temperaturen an die Stellen im Ofen liefern, an denen sich die Teile befinden.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00fcr Betreiber von Ipsen-Vakuum\u00f6fen gibt es zwei Arten von Thermoelementen, die am h\u00e4ufigsten verwendet werden \u2013 die semipermanenten <strong>Steuerung und \u00dcbertemperatur<\/strong> <strong>Thermoelemente<\/strong>, sowie wiederverwendbare und Einwegartikel <strong>Arbeit<\/strong> <strong>Thermoelemente<\/strong> die f\u00fcr Produktions- und Gleichm\u00e4\u00dfigkeitsuntersuchungen verwendet werden.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"eae6e2\" data-has-transparency=\"false\" style=\"--dominant-color: #eae6e2;\" loading=\"lazy\" decoding=\"async\" width=\"1033\" height=\"710\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949.avif\" alt=\"Table showing types of thermocouples, material, and temperature range\" class=\"wp-image-13206 not-transparent\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949.avif 1033w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949-300x206.avif 300w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949-1024x704.avif 1024w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949-768x528.avif 768w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949-18x12.avif 18w\" sizes=\"auto, (max-width: 1033px) 100vw, 1033px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Regel- und \u00dcbertemperatur-Thermoelemente<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Die durch die Seite des Ofens hindurchf\u00fchrenden Regel- und \u00dcbertemperatur-Thermoelemente sind hochentwickelte, empfindliche technische Bauteile. Die hier am h\u00e4ufigsten verwendeten Thermoelementtypen sind <strong>Typ S, R, <\/strong>oder <strong>B<\/strong>. <em>(Siehe Grafik)<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In einem Beispiel verl\u00e4uft ein Platin-Rhodium-Draht vom <strong>Anschlussstecker<\/strong> durch eine <strong>Inconel-Rohr<\/strong> an der Au\u00dfenseite des Ofens, dann durch einen inneren <strong>Keramikh\u00fclse <\/strong>die sich im Inneren des Ofens bildet. <em>(Siehe Bilder)<\/em> Das Thermoelement wird au\u00dferhalb des Ofens mit einer Kupplung befestigt, deren Tiefe eingestellt werden kann. Die Einf\u00fchrtiefe des Regelthermoelements muss pr\u00e4zise sein und gemessen werden, da es die Arbeitstemperatur des Ofens regelt. Dies kann \u00fcber das Bestehen oder Nichtbestehen einer Temperaturgleichm\u00e4\u00dfigkeitspr\u00fcfung (TUS) entscheiden.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"9b5b4d\" data-has-transparency=\"false\" style=\"--dominant-color: #9b5b4d;\" loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"700\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Control-TC-1.avif\" alt=\"Control thermocouple for vacuum furnace\" class=\"wp-image-13208 not-transparent\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Control-TC-1.avif 500w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Control-TC-1-214x300.avif 214w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Control-TC-1-9x12.avif 9w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"888a89\" data-has-transparency=\"false\" style=\"--dominant-color: #888a89;\" loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"700\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Control-Overtemp-Mount-A-1.avif\" alt=\"Control and Overtemp thermocouples exterior view of vacuum furnace\" class=\"wp-image-13209 not-transparent\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Control-Overtemp-Mount-A-1.avif 500w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Control-Overtemp-Mount-A-1-214x300.avif 214w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Control-Overtemp-Mount-A-1-9x12.avif 9w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"332e2e\" data-has-transparency=\"false\" style=\"--dominant-color: #332e2e;\" loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"700\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouples-inside.avif\" alt=\"Control and Overtemp thermocouples interior view of vacuum furnace\" class=\"wp-image-13210 not-transparent\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouples-inside.avif 500w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouples-inside-214x300.avif 214w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouples-inside-9x12.avif 9w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Im Inneren ragen die Keramikspitzen der Regel- und \u00dcbertemperatur-Thermoelemente etwas \u00fcber die Heizelemente hinaus, wo sie ihre Messwerte an die SPS zur\u00fcckmelden k\u00f6nnen. Sie sind empfindlich genug, um Messungen mit einer Genauigkeit von null bis 2 Grad Fahrenheit durchzuf\u00fchren, einem Bereich, der durch die Anforderungen des Prozesses und die Normen AMS 2750 vorgegeben ist.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Jedes dieser Thermoelemente hat eine bestimmte Aufgabe zu erf\u00fcllen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Das Regelthermoelement gibt Informationen an die SPS zur\u00fcck, sodass die Steuerung entscheiden kann, ob die Leistung der Elemente erh\u00f6ht und die Temperatur angehoben, die Leistung der Elemente reduziert und die Temperatur gesenkt oder der aktuelle Status beibehalten werden soll.<\/li>\n\n\n\n<li>\u00dcbertemperatur-Thermoelemente dienen der Prozesssicherheit und alarmieren die Ofensteuerung, wenn die Temperatur im Ofen die in der Rezeptur vorgegebene Temperatur \u00fcberschreitet. Sie k\u00f6nnen auch als Sicherheitseinrichtung f\u00fcr die maximale Temperatur der Anlage dienen, um Sch\u00e4den an Teilen und Ofenkomponenten, einschlie\u00dflich der Hei\u00dfzone, zu verhindern.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Um die Genauigkeit bei jedem Prozess zu gew\u00e4hrleisten, sollten diese beiden Sonden dieselben Werte anzeigen. In bestimmten \u00d6fen kann die Empfindlichkeitsgenauigkeit der Regelthermoelemente dazu f\u00fchren, dass das Ergebnis einer Temperaturgleichm\u00e4\u00dfigkeitspr\u00fcfung innerhalb eines bestimmten Arbeitsbereichs eine Abweichung von plus oder minus 5 Grad Fahrenheit oder plus oder minus 10 Grad Fahrenheit aufweist, basierend auf dem Betriebsbereich des Vakuumofens und der AMS-Qualifikationsklasse. Das ist unglaublich genau f\u00fcr Systeme, die zwischen 1.000 Grad Fahrenheit und 2.500 Grad Fahrenheit betrieben werden k\u00f6nnen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Da ihre Keramikspitzen in den hei\u00dfen Bereich gelangen, in dem Teile geladen und entladen werden, ist es wichtig, Ersatzthermoelemente zur Hand zu haben. Es kommt nicht selten vor, dass eines dieser Thermoelemente abgesplittert oder zerbrochen ist, wenn eine Charge nicht sicher in den Ofen geladen wurde.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ipsen empfiehlt au\u00dferdem, die Temperaturgenauigkeitsabweichung eines Thermoelements mindestens einmal pro Jahr zu \u00fcberpr\u00fcfen und das Thermoelement zu ersetzen, wenn diese Abweichung \u00fcber die Zertifizierung des Thermoelements hinausgeht. Zur Ermittlung des Abweichungsstatus kann eine Systemgenauigkeitspr\u00fcfung durchgef\u00fchrt werden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Arbeits- und Mess-Thermoelemente<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Arbeits- und Mess-Thermoelemente werden h\u00e4ufig als Drahtspulen oder als Mehrleiter-Baugruppen geliefert. Sie bestehen in der Regel aus Legierungen, die Elemente wie Nickel, Chrom, Silizium, Aluminium oder Magnesium enthalten. Die f\u00fcr Arbeits- und Messzwecke am h\u00e4ufigsten verwendeten Kategorien von Thermoelementen sind&nbsp;<strong>Typ K&nbsp;<\/strong>oder<strong>&nbsp;Typ N.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Arbeits- und Mess-Thermoelemente werden \u00fcber die Anschlussleiste an der Vorderseite des Ofens an die SPS angeschlossen und dann durch den Ofen zu bestimmten Punkten an einer Vorrichtung gef\u00fchrt, um die Gleichm\u00e4\u00dfigkeit der W\u00e4rme \u00fcber den gesamten Bereich der Vorrichtung zu \u00fcberpr\u00fcfen.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"8a4c38\" data-has-transparency=\"false\" loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Work-TC-2.avif\" alt=\"Work thermocouple\" class=\"wp-image-13213 not-transparent\" style=\"--dominant-color: #8a4c38; object-fit:cover\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Work-TC-2.avif 500w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Work-TC-2-300x300.avif 300w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Work-TC-2-150x150.avif 150w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Work-TC-2-12x12.avif 12w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"7e7978\" data-has-transparency=\"false\" style=\"--dominant-color: #7e7978;\" loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/TUS-Hot-Zone.avif\" alt=\"Temperature Uniformity Survey inside a vacuum furnace\" class=\"wp-image-13216 not-transparent\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/TUS-Hot-Zone.avif 500w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/TUS-Hot-Zone-300x300.avif 300w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/TUS-Hot-Zone-150x150.avif 150w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/TUS-Hot-Zone-12x12.avif 12w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Obwohl sie einige Male verwendet werden k\u00f6nnen, sind Arbeits- und Mess-Thermoelemente relativ kosteng\u00fcnstig und gelten allgemein als Verbrauchsmaterial \u2013 sie werden verwendet und anschlie\u00dfend entsorgt oder recycelt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sowohl Arbeits- als auch Mess-Thermoelemente werden in der Regel in Zw\u00f6lfer-Sets betrieben. Dadurch k\u00f6nnen Bediener die Temperaturgleichm\u00e4\u00dfigkeit \u00fcber verschiedene Zonen hinweg und innerhalb verschiedener Bereiche ihrer Arbeitslast \u00fcberwachen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mess-Thermoelemente werden in der Regel f\u00fcr interne und externe Qualit\u00e4tssicherungssysteme, Diagnosen und Tests verwendet. An einer herk\u00f6mmlichen Vorrichtung zur \u00dcberpr\u00fcfung der Temperaturgleichm\u00e4\u00dfigkeit werden neun Punkte \u00fcberwacht, um sicherzustellen, dass der Ofen die W\u00e4rme gleichm\u00e4\u00dfig im gesamten Arbeitsbereich verteilt. Zwei weitere Thermoelemente k\u00f6nnen verwendet werden, um zu \u00fcberpr\u00fcfen, ob die Regel- und \u00dcbertemperatur-Thermoelemente konsistente Werte melden. Das verbleibende Thermoelement dient als Reserve, mit der Bediener einen bestimmten Ort innerhalb der Hei\u00dfzone oder einen bestimmten Ort innerhalb der Anlage \u00fcberwachen k\u00f6nnen, an dem in der Regel eine h\u00f6here Teiledichte herrscht.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Arbeitsthermokoppler k\u00f6nnen w\u00e4hrend eines Produktionslaufs verwendet werden, um die Genauigkeit eines Prozesses zu testen und zu \u00fcberpr\u00fcfen. Arbeitsthermokoppler werden an Teilehalterungen, Querschnitten von Teilen oder in Teilen mit komplexer Geometrie angebracht und k\u00f6nnen die Wirksamkeit eines Prozesses melden, wodurch Endbenutzer bessere Rezepturen zur Optimierung der thermischen Verarbeitungsergebnisse entwickeln k\u00f6nnen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mit der Erweiterung der Arbeitsbereiche erm\u00f6glicht die Skalierbarkeit von Thermoelementen in Zw\u00f6lfergruppen eine genauere Pr\u00fcfung innerhalb der Hei\u00dfzone. Jedes Raster kann einen bestimmten Abschnitt der Hei\u00dfzone darstellen, sodass Diagnosen und Pr\u00fcfungen in gr\u00f6\u00dferen Systemen, in denen die Gleichm\u00e4\u00dfigkeit schwieriger einzustellen ist, vereinfacht werden. Die AMS 2750-Normen legen fest, wie viele Thermoelemente basierend auf dem Volumen der Hei\u00dfzone in Kubikfu\u00df und der von Ihnen verwendeten Instrumentengruppe erforderlich sind.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Abschlie\u00dfende \u00dcberlegungen<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Auf dem Markt gibt es eine gro\u00dfe Auswahl an Thermoelementen, die jeweils f\u00fcr die Temperaturmessung in unterschiedlichen Umgebungen zust\u00e4ndig sind. Wenn man die Funktion jedes Thermoelements innerhalb eines Systems versteht, l\u00e4sst sich leichter erkl\u00e4ren, wie ein bestimmtes Thermoelement funktioniert, warum ein Typ teurer ist als ein anderer und ob man einen alternativen Typ in Betracht ziehen sollte, der den Produktionsanforderungen besser entspricht.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Haben Sie eine allgemeine Frage zu Thermoelementen? E-Mail <a href=\"mailto:parts@ipsenusa.com\">parts@ipsenusa.com<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ipsenglobal.com\/de\/parts-request-quote-form\/\" target=\"_blank\" rel=\"noreferrer noopener\">Fordern Sie hier ein Angebot f\u00fcr Thermoelemente oder andere Teile an.<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Von Chuck Reed, Senior Ipsen Customer Service Sales Specialist Thermoelemente spielen eine entscheidende Rolle bei der W\u00e4rmebehandlung, da sie genaue Temperaturdaten liefern, die einen sicheren und gleichm\u00e4\u00dfigen Betrieb von Ofensystemen gew\u00e4hrleisten. Sie sind<\/p>","protected":false},"author":7,"featured_media":0,"menu_order":0,"template":"","meta":{"_acf_changed":false,"_tec_requires_first_save":true,"_searchwp_excluded":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"_EventAllDay":false,"_EventTimezone":"","_EventStartDate":"","_EventEndDate":"","_EventStartDateUTC":"","_EventEndDateUTC":"","_EventShowMap":false,"_EventShowMapLink":false,"_EventURL":"","_EventCost":"","_EventCostDescription":"","_EventCurrencySymbol":"","_EventCurrencyCode":"","_EventCurrencyPosition":"","_EventDateTimeSeparator":"","_EventTimeRangeSeparator":"","_EventOrganizerID":[],"_EventVenueID":[],"_OrganizerEmail":"","_OrganizerPhone":"","_OrganizerWebsite":"","_VenueAddress":"","_VenueCity":"","_VenueCountry":"","_VenueProvince":"","_VenueState":"","_VenueZip":"","_VenuePhone":"","_VenueURL":"","_VenueStateProvince":"","_VenueLat":"","_VenueLng":"","_VenueShowMap":false,"_VenueShowMapLink":false,"_tribe_blocks_recurrence_rules":"","_tribe_blocks_recurrence_description":"","_tribe_blocks_recurrence_exclusions":"","_ecp_custom_2":"","footnotes":""},"categories":[7],"tags":[262,680,681,75],"class_list":["post-13203","knowledge-center","type-knowledge-center","status-publish","hentry","category-technical-article","tag-controls","tag-furnace","tag-thermocouples","tag-vacuum-furnace"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Vacuum Furnace Thermocouples - Ipsen Global<\/title>\n<meta name=\"description\" content=\"Learn how different thermocouples work together to deliver critical information from a vacuum furnace hot zone to the PLC.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/vacuum-furnace-thermocouples\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Vacuum Furnace Thermocouples - Ipsen Global\" \/>\n<meta property=\"og:description\" content=\"Learn how different thermocouples work together to deliver critical information from a vacuum furnace hot zone to the PLC.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/vacuum-furnace-thermocouples\/\" \/>\n<meta property=\"og:site_name\" content=\"Ipsen Global\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/IpsenUSA\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-11T16:32:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949.avif\" \/>\n\t<meta property=\"og:image:width\" content=\"1033\" \/>\n\t<meta property=\"og:image:height\" content=\"710\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ipsenusa\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"7\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"TechArticle\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/\"},\"author\":{\"name\":\"Courtney Kerch\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/person\\\/8fb2c2ce715f8b2c86dd1ab9f3021543\"},\"headline\":\"Vacuum Furnace Thermocouples\",\"datePublished\":\"2025-12-05T15:18:00+00:00\",\"dateModified\":\"2026-03-11T16:32:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/\"},\"wordCount\":1158,\"publisher\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Thermocouple-Types-1-e1764694622949.avif\",\"keywords\":[\"controls\",\"Furnace\",\"Thermocouples\",\"vacuum furnace\"],\"articleSection\":[\"Technical Article\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/\",\"name\":\"Vacuum Furnace Thermocouples - Ipsen Global\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Thermocouple-Types-1-e1764694622949.avif\",\"datePublished\":\"2025-12-05T15:18:00+00:00\",\"dateModified\":\"2026-03-11T16:32:12+00:00\",\"description\":\"Learn how different thermocouples work together to deliver critical information from a vacuum furnace hot zone to the PLC.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Thermocouple-Types-1-e1764694622949.avif\",\"contentUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Thermocouple-Types-1-e1764694622949.avif\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/vacuum-furnace-thermocouples\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ipsenglobal.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge Center\",\"item\":\"https:\\\/\\\/dipsen.wpengine.com\\\/knowledge-center\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Vacuum Furnace Thermocouples\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#website\",\"url\":\"https:\\\/\\\/dipsen.wpengine.com\\\/\",\"name\":\"Ipsen Global\",\"description\":\"Strengthening Innovation Worldwide\",\"publisher\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dipsen.wpengine.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\",\"name\":\"Ipsen\",\"url\":\"https:\\\/\\\/dipsen.wpengine.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Ipsen-Pantone186C_Large_W_White.jpg\",\"contentUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Ipsen-Pantone186C_Large_W_White.jpg\",\"width\":1090,\"height\":545,\"caption\":\"Ipsen\"},\"image\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/IpsenUSA\",\"https:\\\/\\\/x.com\\\/ipsenusa\",\"https:\\\/\\\/www.instagram.com\\\/ipsenusa\\\/\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/ipsenvideos\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/person\\\/8fb2c2ce715f8b2c86dd1ab9f3021543\",\"name\":\"Courtney Kerch\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"caption\":\"Courtney Kerch\"},\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/de\\\/author\\\/ckerch\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Vakuumofen-Thermoelemente \u2013 Ipsen Global","description":"Erfahren Sie, wie verschiedene Thermoelemente zusammenarbeiten, um wichtige Informationen aus der Heizzone eines Vakuumofens an die SPS zu \u00fcbermitteln.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ipsenglobal.com\/de\/knowledge-center\/vacuum-furnace-thermocouples\/","og_locale":"de_DE","og_type":"article","og_title":"Vacuum Furnace Thermocouples - Ipsen Global","og_description":"Learn how different thermocouples work together to deliver critical information from a vacuum furnace hot zone to the PLC.","og_url":"https:\/\/ipsenglobal.com\/de\/knowledge-center\/vacuum-furnace-thermocouples\/","og_site_name":"Ipsen Global","article_publisher":"https:\/\/www.facebook.com\/IpsenUSA","article_modified_time":"2026-03-11T16:32:12+00:00","og_image":[{"width":1033,"height":710,"url":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949.avif","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@ipsenusa","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"7\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"TechArticle","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/#article","isPartOf":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/"},"author":{"name":"Courtney Kerch","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/person\/8fb2c2ce715f8b2c86dd1ab9f3021543"},"headline":"Vacuum Furnace Thermocouples","datePublished":"2025-12-05T15:18:00+00:00","dateModified":"2026-03-11T16:32:12+00:00","mainEntityOfPage":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/"},"wordCount":1158,"publisher":{"@id":"https:\/\/dipsen.wpengine.com\/#organization"},"image":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/#primaryimage"},"thumbnailUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949.avif","keywords":["controls","Furnace","Thermocouples","vacuum furnace"],"articleSection":["Technical Article"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/","url":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/","name":"Vakuumofen-Thermoelemente \u2013 Ipsen Global","isPartOf":{"@id":"https:\/\/dipsen.wpengine.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/#primaryimage"},"image":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/#primaryimage"},"thumbnailUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949.avif","datePublished":"2025-12-05T15:18:00+00:00","dateModified":"2026-03-11T16:32:12+00:00","description":"Erfahren Sie, wie verschiedene Thermoelemente zusammenarbeiten, um wichtige Informationen aus der Heizzone eines Vakuumofens an die SPS zu \u00fcbermitteln.","breadcrumb":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/#primaryimage","url":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949.avif","contentUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/12\/Thermocouple-Types-1-e1764694622949.avif"},{"@type":"BreadcrumbList","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/vacuum-furnace-thermocouples\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ipsenglobal.com\/"},{"@type":"ListItem","position":2,"name":"Knowledge Center","item":"https:\/\/dipsen.wpengine.com\/knowledge-center\/"},{"@type":"ListItem","position":3,"name":"Vacuum Furnace Thermocouples"}]},{"@type":"WebSite","@id":"https:\/\/dipsen.wpengine.com\/#website","url":"https:\/\/dipsen.wpengine.com\/","name":"Ipsen Global","description":"St\u00e4rkung der Innovation weltweit","publisher":{"@id":"https:\/\/dipsen.wpengine.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dipsen.wpengine.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/dipsen.wpengine.com\/#organization","name":"Ipsen","url":"https:\/\/dipsen.wpengine.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/logo\/image\/","url":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/10\/Ipsen-Pantone186C_Large_W_White.jpg","contentUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/10\/Ipsen-Pantone186C_Large_W_White.jpg","width":1090,"height":545,"caption":"Ipsen"},"image":{"@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/IpsenUSA","https:\/\/x.com\/ipsenusa","https:\/\/www.instagram.com\/ipsenusa\/","https:\/\/www.youtube.com\/user\/ipsenvideos"]},{"@type":"Person","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/person\/8fb2c2ce715f8b2c86dd1ab9f3021543","name":"Courtney Kerch","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","caption":"Courtney Kerch"},"url":"https:\/\/ipsenglobal.com\/de\/author\/ckerch\/"}]}},"taxonomy_info":{"category":[{"value":7,"label":"Technical Article"}],"post_tag":[{"value":262,"label":"controls"},{"value":680,"label":"Furnace"},{"value":681,"label":"Thermocouples"},{"value":75,"label":"vacuum furnace"}]},"featured_image_src_large":false,"author_info":{"display_name":"Courtney Kerch","author_link":"https:\/\/ipsenglobal.com\/de\/author\/ckerch\/"},"comment_info":"","_links":{"self":[{"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/knowledge-center\/13203","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/knowledge-center"}],"about":[{"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/types\/knowledge-center"}],"author":[{"embeddable":true,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/users\/7"}],"version-history":[{"count":14,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/knowledge-center\/13203\/revisions"}],"predecessor-version":[{"id":14198,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/knowledge-center\/13203\/revisions\/14198"}],"wp:attachment":[{"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/media?parent=13203"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/categories?post=13203"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/tags?post=13203"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}