{"id":762,"date":"2015-10-01T14:56:00","date_gmt":"2015-10-01T19:56:00","guid":{"rendered":"http:\/\/www.IpsenHarold.com\/?p=762"},"modified":"2025-09-29T19:57:04","modified_gmt":"2025-09-29T19:57:04","slug":"installing-a-new-hot-zone","status":"publish","type":"knowledge-center","link":"https:\/\/ipsenglobal.com\/de\/knowledge-center\/installing-a-new-hot-zone\/","title":{"rendered":"Ein Blick ins Innere des Ofens: Installation einer neuen Hot Zone"},"content":{"rendered":"<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2016\/07\/B_Roll.02_49_34_17.Still006-1024x576.jpg\" alt=\"Ipsen hot zone installation\" class=\"wp-image-3543\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2016\/07\/B_Roll.02_49_34_17.Still006-1024x576.jpg 1024w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2016\/07\/B_Roll.02_49_34_17.Still006-300x169.jpg 300w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2016\/07\/B_Roll.02_49_34_17.Still006-768x432.jpg 768w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2016\/07\/B_Roll.02_49_34_17.Still006-1536x864.jpg 1536w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2016\/07\/B_Roll.02_49_34_17.Still006-18x10.jpg 18w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2016\/07\/B_Roll.02_49_34_17.Still006.jpg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In einem fr\u00fcheren Beitrag dieser Serie haben wir die Schritte f\u00fcr <a href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/a-look-inside-the-furnace-removing-the-hot-zone-from-your-furnace\/\">Entfernen einer alten Heizzone aus Ihrem Ofen<\/a>. In diesem Beitrag werden wir den Prozess vervollst\u00e4ndigen, indem wir die wichtigsten Schritte f\u00fcr die ordnungsgem\u00e4\u00dfe Installation einer neuen Heizzone besprechen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>Anmerkung:<\/strong> Genau wie bei der Entnahme sind diese Schritte spezifisch f\u00fcr bestimmte Ofentypen, wie den Ipsen TurboTreater<sup>\u00ae<\/sup>TITAN<sup>\u00ae<\/sup> und horizontale Standardmodelle. Unabh\u00e4ngig von Ihrer Heizzone und Ihrem Ofenmodell empfehlen wir Ihnen, das Handbuch Ihres Ofens oder einen Serviceexperten zu konsultieren, bevor Sie mit der Installation beginnen.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zur Erinnerung: Nachdem Sie die hei\u00dfe Zone entfernt haben, ist dies der ideale Zeitpunkt, um die Innenwand der Kammer zu reinigen und die Duktordichtung und die Thermoelementbuchsenplatte wieder anzubringen. Dann k\u00f6nnen Sie die neue hei\u00dfe Zone einbauen. Im Gro\u00dfen und Ganzen ist der Prozess \u00e4hnlich, aber es gibt einige Unterschiede, die im Folgenden beschrieben werden.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">1. Das Lastaufnahmemittelsystem grob einpassen und nivellieren und die Herdpfosten montieren.<\/h5>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Experten-Tipp:<\/strong> Wenn Sie sich bei diesem Schritt so weit wie m\u00f6glich an die Waage halten, ist es viel einfacher, die Feinabstimmung und die endg\u00fcltige Nivellierung des Feuerstellensystems w\u00e4hrend des Installationsprozesses vorzunehmen.<\/p>\n<\/blockquote>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Bringen Sie alle Herdpfosten an ihrem urspr\u00fcnglichen Standort an, wie vor dem Entfernen der alten Heizzone angegeben, und bestimmen Sie den h\u00f6chsten Pfosten.\n<ul class=\"wp-block-list\">\n<li>Vergleichen Sie die neue Herdh\u00f6he mit der urspr\u00fcnglichen H\u00f6he. Die von Ihnen gew\u00fcnschte H\u00f6he h\u00e4ngt von der Konstruktion des Laders ab, der in der Lage sein muss, die maximale Last weit \u00fcber die Feuerstelle zu heben und diese zu verlassen.\n<ul class=\"wp-block-list\">\n<li>Passen Sie alle anderen Pfosten bis auf 0,015 Zoll an den h\u00f6chsten Pfosten an.<\/li>\n\n\n\n<li>Die Abrundung der Unterlegplatten in der N\u00e4he der Gr\u00f6\u00dfe der Herdpfostensockel ist vorzuziehen.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Entfernen Sie die Feuerstelle, lassen Sie aber die Unterlegscheiben in den Fassungen.<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\">2. Installieren Sie die hei\u00dfe Zone.<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Setzen Sie die hei\u00dfe Zone in den Ofen ein und senken Sie sie ab, so dass der Gro\u00dfteil des Gewichts noch vom 10.000-Pfund-Gabelstapler getragen wird.\n<ul class=\"wp-block-list\">\n<li>Es ist von Vorteil, einen Gabelstapler zu haben, der von links nach rechts fahren kann, um die Positionierung der neuen hei\u00dfen Zone w\u00e4hrend der Installation zu unterst\u00fctzen. <\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Positionieren Sie die hei\u00dfe Zone so, dass die L\u00f6cher f\u00fcr die Stromdurchf\u00fchrung, die L\u00f6cher f\u00fcr das Thermoelement (TC) und die L\u00f6cher f\u00fcr den Herdpfosten so nah wie m\u00f6glich beieinander liegen.<\/li>\n\n\n\n<li>Senken Sie die hei\u00dfe Zone so ab, dass alle R\u00e4der und ihr gesamtes Gewicht auf den St\u00fctzschienen stehen.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Experten-Tipp: <\/strong>Wenn nicht alle R\u00e4der der hei\u00dfen Zone die St\u00fctzschienen ber\u00fchren, m\u00fcssen die R\u00e4der unterlegt werden, bis die hei\u00dfe Zone stabil auf den Schienen aufliegt.<\/p>\n<\/blockquote>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Bei verschraubten Heizzonen schieben Sie die Heizzone zur\u00fcck in den Ofen, bis alle Bolzen auf der R\u00fcckseite der Heizzone den Flansch des K\u00fchlsystems durchdringen (pr\u00fcfen Sie dies durch das offene Motorgeh\u00e4use). Bei Gleitdichtungen schieben Sie die hei\u00dfe Zone einfach zur\u00fcck in den Ofen.<\/li>\n\n\n\n<li>\u00dcberpr\u00fcfen Sie nochmals alle TK-Durchf\u00fchrungen auf korrekte Ausrichtung.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Experten-Tipp:<\/strong> Die TK-L\u00f6cher sollten so angeordnet sein, dass ein D\u00fcbel (in \u00e4hnlicher Gr\u00f6\u00dfe wie die Thermoelemente) von der Au\u00dfenseite des Ofens bis zur Innenseite der hei\u00dfen Zone hindurchgef\u00fchrt werden kann, ohne etwas an den Seiten zu ber\u00fchren.<\/p>\n<\/blockquote>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Richten Sie die L\u00f6cher f\u00fcr den Herdpfosten und die Stromdurchf\u00fchrung nach demselben Verfahren wie die TC-L\u00f6cher aus. Nehmen Sie eine Feinabstimmung der Ausrichtung vor, indem Sie Unterlegscheiben unter den R\u00e4dern der Heizzone hinzuf\u00fcgen oder abziehen.<\/li>\n<\/ul>\n\n\n\n<h5 class=\"wp-block-heading\">3. Installieren Sie das Herdsystem zur Unterst\u00fctzung der Last.<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">4. Montieren Sie die Stromdurchf\u00fchrungsbaugruppen (schlie\u00dfen Sie sie jedoch noch nicht an) und beschichten Sie die Silikon\/Buna-O-Ringe leicht mit einem vakuumtauglichen Schmiermittel.<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">5. Montieren Sie die Regel- und \u00dcbertemperaturf\u00fchler.<\/h5>\n\n\n\n<h5 class=\"wp-block-heading\">6. Wenn Sie eine Hei\u00dfzone mit Gleitringdichtung haben, fahren Sie mit Schritt 7 fort. Wenn Sie eine Schraubdichtung haben, folgen Sie diesen Schritten:<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Bringen Sie Sicherungsmuttern und Unterlegscheiben an den Schrauben an, die aus dem K\u00fchlsystemflansch herausragen.\n<ul class=\"wp-block-list\">\n<li>Verwenden Sie eine lange Verl\u00e4ngerung (48\"), um die \u00dcbergangsplatte zu erreichen. Die Muttern sollten ungef\u00e4hr auf gleicher H\u00f6he mit der Oberfl\u00e4che der Ventilatorfl\u00fcgel sein und k\u00f6nnen durch die R\u00fcckseite des Motorgeh\u00e4uses gesehen werden. <\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Experten-Tipp:<\/strong> Achten Sie darauf, dass alle Muttern und Unterlegscheiben vorhanden sind. Lose Teile, die beim Starten in der N\u00e4he des Gebl\u00e4ses liegen, k\u00f6nnen die K\u00fchlschlangen schwer besch\u00e4digen.<\/p>\n<\/blockquote>\n\n\n\n<h5 class=\"wp-block-heading\">7. Schlie\u00dfen Sie die Stromdurchf\u00fchrungsbaugruppen an.<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Es wird empfohlen, bei der Installation der hei\u00dfen Zone neue Molybd\u00e4nteile zu verwenden. Neue Muttern und Stangen sind in der Regel im Lieferumfang einer neuen Hei\u00dfen Zone enthalten.<\/li>\n<\/ul>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\"><strong>Experten-Tipp:<\/strong> Moly-Muttern sollten mit zwei 6\u2033-Maulschl\u00fcsseln angezogen werden. Es sollte darauf geachtet werden, dass die Moly-Muttern nicht zu fest angezogen werden, da sie sonst brechen und\/oder rei\u00dfen.<\/p>\n<\/blockquote>\n\n\n\n<h5 class=\"wp-block-heading\">8. Montieren Sie das Kopfpaket.<\/h5>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Setzen Sie die Drahtverriegelungsstifte in die Buchsen an der T\u00fcr in ihrer urspr\u00fcnglichen Position ein.<\/li>\n\n\n\n<li>Bringen Sie die Sechskantmuttern in der Tiefe an, die vor dem Entfernen des urspr\u00fcnglichen Kopfpakets angegeben wurde.<\/li>\n\n\n\n<li>Verwenden Sie einen Br\u00fcckenkran, um das Kopfpaket zu st\u00fctzen, w\u00e4hrend Sie es auf den Drahtverriegelungsstiften positionieren und gem\u00e4\u00df der Montagezeichnung f\u00fcr den hei\u00dfen Bereich befestigen.<\/li>\n\n\n\n<li>\u00dcberpr\u00fcfen Sie nach dem Einbau den T\u00fcrspalt zwischen dem Kopfpaket und der hei\u00dfen Zone. Der Spalt sollte die gleiche Tiefe haben, wie sie zuvor bei der <a href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/a-look-inside-the-furnace-removing-the-hot-zone-from-your-furnace\/\">Entnahmevorgang<\/a>. Nehmen Sie die erforderlichen Einstellungen vor und verwenden Sie die Montagezeichnung als Referenz.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Sie diese Schritte abgeschlossen haben, sollte die hei\u00dfe Zone vollst\u00e4ndig installiert sein. Die Heizelemente m\u00fcssen jedoch noch installiert werden. Es ist wichtig zu beachten, dass die Installation der Heizelemente von Ofen zu Ofen unterschiedlich sein kann, je nach Art der verwendeten Heizelemente.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Sie weitere Informationen, Unterst\u00fctzung bei der Installation einer neuen Heizzone oder von Heizelementen und\/oder ein Angebot f\u00fcr die Installation einer neuen Heizzone w\u00fcnschen, wenden Sie sich bitte an den Ipsen-Kundendienst unter <strong>+49 172 253 3910<\/strong> (07:30 - 15:00 Uhr: +49 2821 804 0 ; 24\/7: +49 172 253 3910)<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Erfahren Sie mehr \u00fcber hei\u00dfe Zonen:<\/p>\n<\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/ask-the-expert-what-to-know-when-youre-shopping-for-a-hot-zone-replacement-or-retrofit\/\">Was Sie \u00fcber Ihre hei\u00dfe Zone wissen m\u00fcssen, wenn Sie sich f\u00fcr einen Ersatz oder eine Nachr\u00fcstung entscheiden<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/molybdenum-hot-zones-are-they-right-for-you\/\">Grundlegende Informationen zur Auswahl einer Molybd\u00e4n-Ganzmetall-Heizzone<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/can-i-replace-a-graphite-hot-zone-with-an-all-metal-one\/\">Kann man eine Graphit-Hei\u00dfzone in eine Ganzmetall-Hei\u00dfzone umwandeln?<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/the-journey-of-a-hot-zone\/\">Erfahren Sie mehr \u00fcber den Prozess der Herstellung und Lieferung einer Ipsen Hot Zone<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/hot-zone-maintenance-for-extending-lifespan\/\">Empfohlene Wartung in hei\u00dfen Zonen<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/spring-cleaning-best-practices-for-vacuum-furnace-maintenance\/\">Bew\u00e4hrte Verfahren f\u00fcr die Reinigung in hei\u00dfen Zonen<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>In einem fr\u00fcheren Beitrag dieser Serie haben wir die Schritte zum Entfernen einer alten Heizzone aus Ihrem Ofen untersucht. In diesem Beitrag werden wir den Prozess abschlie\u00dfen, indem wir Folgendes besprechen<\/p>","protected":false},"author":7,"featured_media":771,"menu_order":0,"template":"","meta":{"_acf_changed":false,"_tec_requires_first_save":true,"_searchwp_excluded":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"_EventAllDay":false,"_EventTimezone":"","_EventStartDate":"","_EventEndDate":"","_EventStartDateUTC":"","_EventEndDateUTC":"","_EventShowMap":false,"_EventShowMapLink":false,"_EventURL":"","_EventCost":"","_EventCostDescription":"","_EventCurrencySymbol":"","_EventCurrencyCode":"","_EventCurrencyPosition":"","_EventDateTimeSeparator":"","_EventTimeRangeSeparator":"","_EventOrganizerID":[],"_EventVenueID":[],"_OrganizerEmail":"","_OrganizerPhone":"","_OrganizerWebsite":"","_VenueAddress":"","_VenueCity":"","_VenueCountry":"","_VenueProvince":"","_VenueState":"","_VenueZip":"","_VenuePhone":"","_VenueURL":"","_VenueStateProvince":"","_VenueLat":"","_VenueLng":"","_VenueShowMap":false,"_VenueShowMapLink":false,"_tribe_blocks_recurrence_rules":"","_tribe_blocks_recurrence_description":"","_tribe_blocks_recurrence_exclusions":"","_ecp_custom_2":"","footnotes":""},"categories":[558],"tags":[25,75],"class_list":["post-762","knowledge-center","type-knowledge-center","status-publish","has-post-thumbnail","hentry","category-blog-post","tag-hot-zone","tag-vacuum-furnace"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>A Look Inside the Furnace: Installing a New Hot Zone - Ipsen Global<\/title>\n<meta name=\"description\" content=\"After removing an old hot zone from your heat treatment furnace, follow these Ipsen-recommended steps for installing a new hot zone.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/installing-a-new-hot-zone\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A Look Inside the Furnace: Installing a New Hot Zone - Ipsen Global\" \/>\n<meta property=\"og:description\" content=\"After removing an old hot zone from your heat treatment furnace, follow these Ipsen-recommended steps for installing a new hot zone.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ipsenglobal.com\/de\/knowledge-center\/installing-a-new-hot-zone\/\" \/>\n<meta property=\"og:site_name\" content=\"Ipsen Global\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/IpsenUSA\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-29T19:57:04+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ipsenusa\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"4\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"TechArticle\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/\"},\"author\":{\"name\":\"Courtney Kerch\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/person\\\/8fb2c2ce715f8b2c86dd1ab9f3021543\"},\"headline\":\"A Look Inside the Furnace: Installing a New Hot Zone\",\"datePublished\":\"2015-10-01T19:56:00+00:00\",\"dateModified\":\"2025-09-29T19:57:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/\"},\"wordCount\":983,\"publisher\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"keywords\":[\"hot zone\",\"vacuum furnace\"],\"articleSection\":[\"Blog Post\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/\",\"name\":\"A Look Inside the Furnace: Installing a New Hot Zone - Ipsen Global\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2015-10-01T19:56:00+00:00\",\"dateModified\":\"2025-09-29T19:57:04+00:00\",\"description\":\"After removing an old hot zone from your heat treatment furnace, follow these Ipsen-recommended steps for installing a new hot zone.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/installing-a-new-hot-zone\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ipsenglobal.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge Center\",\"item\":\"https:\\\/\\\/dipsen.wpengine.com\\\/knowledge-center\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"A Look Inside the Furnace: Installing a New Hot Zone\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#website\",\"url\":\"https:\\\/\\\/dipsen.wpengine.com\\\/\",\"name\":\"Ipsen Global\",\"description\":\"Strengthening Innovation Worldwide\",\"publisher\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dipsen.wpengine.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\",\"name\":\"Ipsen\",\"url\":\"https:\\\/\\\/dipsen.wpengine.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Ipsen-Pantone186C_Large_W_White.jpg\",\"contentUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Ipsen-Pantone186C_Large_W_White.jpg\",\"width\":1090,\"height\":545,\"caption\":\"Ipsen\"},\"image\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/IpsenUSA\",\"https:\\\/\\\/x.com\\\/ipsenusa\",\"https:\\\/\\\/www.instagram.com\\\/ipsenusa\\\/\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/ipsenvideos\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/person\\\/8fb2c2ce715f8b2c86dd1ab9f3021543\",\"name\":\"Courtney Kerch\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"caption\":\"Courtney Kerch\"},\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/de\\\/author\\\/ckerch\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ein Blick ins Innere des Ofens: Installation einer neuen hei\u00dfen Zone - Ipsen Global","description":"Nachdem Sie eine alte Heizzone aus Ihrem W\u00e4rmebehandlungsofen entfernt haben, befolgen Sie die von Ipsen empfohlenen Schritte zur Installation einer neuen Heizzone.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ipsenglobal.com\/de\/knowledge-center\/installing-a-new-hot-zone\/","og_locale":"de_DE","og_type":"article","og_title":"A Look Inside the Furnace: Installing a New Hot Zone - Ipsen Global","og_description":"After removing an old hot zone from your heat treatment furnace, follow these Ipsen-recommended steps for installing a new hot zone.","og_url":"https:\/\/ipsenglobal.com\/de\/knowledge-center\/installing-a-new-hot-zone\/","og_site_name":"Ipsen Global","article_publisher":"https:\/\/www.facebook.com\/IpsenUSA","article_modified_time":"2025-09-29T19:57:04+00:00","twitter_card":"summary_large_image","twitter_site":"@ipsenusa","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"4\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"TechArticle","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/#article","isPartOf":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/"},"author":{"name":"Courtney Kerch","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/person\/8fb2c2ce715f8b2c86dd1ab9f3021543"},"headline":"A Look Inside the Furnace: Installing a New Hot Zone","datePublished":"2015-10-01T19:56:00+00:00","dateModified":"2025-09-29T19:57:04+00:00","mainEntityOfPage":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/"},"wordCount":983,"publisher":{"@id":"https:\/\/dipsen.wpengine.com\/#organization"},"image":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/#primaryimage"},"thumbnailUrl":"","keywords":["hot zone","vacuum furnace"],"articleSection":["Blog Post"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/","url":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/","name":"Ein Blick ins Innere des Ofens: Installation einer neuen hei\u00dfen Zone - Ipsen Global","isPartOf":{"@id":"https:\/\/dipsen.wpengine.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/#primaryimage"},"image":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/#primaryimage"},"thumbnailUrl":"","datePublished":"2015-10-01T19:56:00+00:00","dateModified":"2025-09-29T19:57:04+00:00","description":"Nachdem Sie eine alte Heizzone aus Ihrem W\u00e4rmebehandlungsofen entfernt haben, befolgen Sie die von Ipsen empfohlenen Schritte zur Installation einer neuen Heizzone.","breadcrumb":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/installing-a-new-hot-zone\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ipsenglobal.com\/"},{"@type":"ListItem","position":2,"name":"Knowledge Center","item":"https:\/\/dipsen.wpengine.com\/knowledge-center\/"},{"@type":"ListItem","position":3,"name":"A Look Inside the Furnace: Installing a New Hot Zone"}]},{"@type":"WebSite","@id":"https:\/\/dipsen.wpengine.com\/#website","url":"https:\/\/dipsen.wpengine.com\/","name":"Ipsen Global","description":"St\u00e4rkung der Innovation weltweit","publisher":{"@id":"https:\/\/dipsen.wpengine.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dipsen.wpengine.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/dipsen.wpengine.com\/#organization","name":"Ipsen","url":"https:\/\/dipsen.wpengine.com\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/logo\/image\/","url":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/10\/Ipsen-Pantone186C_Large_W_White.jpg","contentUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/10\/Ipsen-Pantone186C_Large_W_White.jpg","width":1090,"height":545,"caption":"Ipsen"},"image":{"@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/IpsenUSA","https:\/\/x.com\/ipsenusa","https:\/\/www.instagram.com\/ipsenusa\/","https:\/\/www.youtube.com\/user\/ipsenvideos"]},{"@type":"Person","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/person\/8fb2c2ce715f8b2c86dd1ab9f3021543","name":"Courtney Kerch","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","caption":"Courtney Kerch"},"url":"https:\/\/ipsenglobal.com\/de\/author\/ckerch\/"}]}},"taxonomy_info":{"category":[{"value":558,"label":"Blog Post"}],"post_tag":[{"value":25,"label":"hot zone"},{"value":75,"label":"vacuum furnace"}]},"featured_image_src_large":false,"author_info":{"display_name":"Courtney Kerch","author_link":"https:\/\/ipsenglobal.com\/de\/author\/ckerch\/"},"comment_info":"","_links":{"self":[{"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/knowledge-center\/762","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/knowledge-center"}],"about":[{"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/types\/knowledge-center"}],"author":[{"embeddable":true,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/users\/7"}],"version-history":[{"count":2,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/knowledge-center\/762\/revisions"}],"predecessor-version":[{"id":12661,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/knowledge-center\/762\/revisions\/12661"}],"wp:attachment":[{"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/media?parent=762"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/categories?post=762"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ipsenglobal.com\/de\/wp-json\/wp\/v2\/tags?post=762"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}