{"id":526,"date":"2019-06-11T15:13:46","date_gmt":"2019-06-11T20:13:46","guid":{"rendered":"http:\/\/www.IpsenHarold.com\/?p=526"},"modified":"2024-12-03T17:08:00","modified_gmt":"2024-12-03T17:08:00","slug":"12-things-to-avoid-when-using-a-diffusion-pump","status":"publish","type":"knowledge-center","link":"https:\/\/ipsenglobal.com\/fr\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/","title":{"rendered":"12 choses \u00e0 \u00e9viter lors de l'utilisation d'une pompe \u00e0 diffusion"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/03\/mikros-113.jpg\" alt=\"Ipsen vacuum furnace diffusion pump\" class=\"wp-image-3589\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/03\/mikros-113.jpg 1024w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/03\/mikros-113-300x169.jpg 300w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/03\/mikros-113-768x432.jpg 768w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/03\/mikros-113-18x10.jpg 18w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p><a href=\"https:\/\/ipsenglobal.com\/fr\/knowledge-center\/how-do-diffusion-pumps-work\/\">Pompes \u00e0 diffusion d'huile<\/a> sont souvent consid\u00e9r\u00e9s comme les merveilles du monde de la pompe \u00e0 vide. Ils sont simples \u00e0 utiliser, n'ont pas de pi\u00e8ces mobiles, n\u00e9cessitent peu d'entretien et sont relativement peu co\u00fbteux.<\/p>\n\n\n\n<p>Cependant, m\u00eame les pompes \u00e0 diffusion ont quelques choses \u00e0 faire et \u00e0 ne pas faire. Vous trouverez ci-dessous une liste de 12 choses que tout utilisateur de four \u00e0 vide devrait \u00e9viter lorsqu'il utilise une pompe \u00e0 diffusion.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ce qu'il ne faut pas faire avec une pompe \u00e0 diffusion<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>Ne pas<\/strong> utiliser des fluides de pompage de substitution.<\/li>\n\n\n\n<li><strong>Ne pas<\/strong> ne pas tenter d'ouvrir les drains ou les bouchons de remplissage si la pompe de diffusion est sous vide (en particulier lorsqu'elle est chaude).<\/li>\n\n\n\n<li><strong>Ne pas<\/strong> laisser la vanne d'entr\u00e9e ouverte lorsque des fuites ou une production continue de gaz provenant de sources situ\u00e9es dans le syst\u00e8me du four provoquent une pression sup\u00e9rieure \u00e0 deux microns pr\u00e8s de l'entr\u00e9e de la pompe. <\/li>\n\n\n\n<li><strong>Ne pas<\/strong> utiliser des appareils de chauffage d'une puissance sup\u00e9rieure \u00e0 celle recommand\u00e9e.<\/li>\n\n\n\n<li><strong>Ne pas<\/strong> faire fonctionner la pompe de diffusion lorsque le niveau de liquide est bas.<\/li>\n\n\n\n<li><strong>Ne pas<\/strong> faire fonctionner la pompe sans que l'eau de refroidissement ne circule dans les serpentins ou sans la pompe d'appoint appropri\u00e9e. Pour les grandes installations, il est conseill\u00e9 d'utiliser des syst\u00e8mes \u00e0 double protection. Les dispositifs thermostatiques prot\u00e8gent g\u00e9n\u00e9ralement la pompe en cas de manque de fluide ou de perte d'eau, mais une d\u00e9faillance du circuit de commande est toujours possible. <\/li>\n\n\n\n<li><strong>Ne pas<\/strong> de neutraliser les dispositifs de s\u00e9curit\u00e9.<\/li>\n\n\n\n<li><strong>Ne pas <\/strong>admettre l'air atmosph\u00e9rique dans la pompe lorsque la pompe \u00e0 diffusion est chaude.<\/li>\n\n\n\n<li><strong>Ne pas<\/strong> ne pas mettre la pompe sous tension si elle n'est pas correctement charg\u00e9e en fluide et si elle n'est pas \u00e9vacu\u00e9e \u00e0 moins de 0,5 Torr.<\/li>\n\n\n\n<li><strong>Ne pas<\/strong> contaminer la pompe avec des vapeurs explosives, des poudres ou des mat\u00e9riaux susceptibles de r\u00e9agir avec les fluides de pompage recommand\u00e9s.<\/li>\n\n\n\n<li><strong>Ne pas<\/strong> faire fonctionner le serpentin de refroidissement rapide si la pompe est hors service. Des condensats nocifs peuvent s'accumuler sur les bornes de l'appareil de chauffage.<\/li>\n\n\n\n<li><strong>Ne pas<\/strong> laisser l'eau de refroidissement de la pompe en marche lorsque la pompe n'est pas en service et qu'elle est expos\u00e9e \u00e0 l'atmosph\u00e8re. Le fait de la laisser en marche peut entra\u00eener une condensation de l'humidit\u00e9 \u00e0 l'int\u00e9rieur de la pompe.<\/li>\n<\/ol>\n\n\n\n<p>Pour toute question relative aux syst\u00e8mes de pompage de four \u00e0 vide, appelez le service client\u00e8le d'Ipsen \u00e0 l'adresse suivante <strong>1-844-GO-IPSEN<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Les pompes \u00e0 diffusion sont souvent consid\u00e9r\u00e9es comme les merveilles du monde du pompage \u00e0 vide. Elles sont simples \u00e0 utiliser, ne comportent aucune pi\u00e8ce mobile, n\u00e9cessitent peu d'entretien et sont relativement peu co\u00fbteuses. Cependant, m\u00eame<\/p>","protected":false},"author":7,"featured_media":2799,"menu_order":0,"template":"","meta":{"_acf_changed":false,"_tec_requires_first_save":true,"_searchwp_excluded":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"_EventAllDay":false,"_EventTimezone":"","_EventStartDate":"","_EventEndDate":"","_EventStartDateUTC":"","_EventEndDateUTC":"","_EventShowMap":false,"_EventShowMapLink":false,"_EventURL":"","_EventCost":"","_EventCostDescription":"","_EventCurrencySymbol":"","_EventCurrencyCode":"","_EventCurrencyPosition":"","_EventDateTimeSeparator":"","_EventTimeRangeSeparator":"","_EventOrganizerID":[],"_EventVenueID":[],"_OrganizerEmail":"","_OrganizerPhone":"","_OrganizerWebsite":"","_VenueAddress":"","_VenueCity":"","_VenueCountry":"","_VenueProvince":"","_VenueState":"","_VenueZip":"","_VenuePhone":"","_VenueURL":"","_VenueStateProvince":"","_VenueLat":"","_VenueLng":"","_VenueShowMap":false,"_VenueShowMapLink":false,"_tribe_blocks_recurrence_rules":"","_tribe_blocks_recurrence_description":"","_tribe_blocks_recurrence_exclusions":"","_ecp_custom_2":"","footnotes":""},"categories":[558,612,654],"tags":[472,75],"class_list":["post-526","knowledge-center","type-knowledge-center","status-publish","has-post-thumbnail","hentry","category-blog-post","category-preventive-maintenance","category-pumping-systems","tag-diffusion-pump","tag-vacuum-furnace"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>12 Things to Avoid When Using a Diffusion Pump - Ipsen Global<\/title>\n<meta name=\"description\" content=\"While diffusion pumps are fairly simple to operate, here are 12 things every vacuum furnace user should avoid when using a diffusion pump.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ipsenglobal.com\/fr\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"12 Things to Avoid When Using a Diffusion Pump - Ipsen Global\" \/>\n<meta property=\"og:description\" content=\"While diffusion pumps are fairly simple to operate, here are 12 things every vacuum furnace user should avoid when using a diffusion pump.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ipsenglobal.com\/fr\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/\" \/>\n<meta property=\"og:site_name\" content=\"Ipsen Global\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/IpsenUSA\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-03T17:08:00+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ipsenusa\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"TechArticle\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/\"},\"author\":{\"name\":\"Courtney Kerch\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/person\\\/8fb2c2ce715f8b2c86dd1ab9f3021543\"},\"headline\":\"12 Things to Avoid When Using a Diffusion Pump\",\"datePublished\":\"2019-06-11T20:13:46+00:00\",\"dateModified\":\"2024-12-03T17:08:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/\"},\"wordCount\":325,\"publisher\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"keywords\":[\"diffusion pump\",\"vacuum furnace\"],\"articleSection\":[\"Blog Post\",\"Preventive Maintenance\",\"Pumping Systems\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/\",\"name\":\"12 Things to Avoid When Using a Diffusion Pump - Ipsen Global\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/#primaryimage\"},\"thumbnailUrl\":\"\",\"datePublished\":\"2019-06-11T20:13:46+00:00\",\"dateModified\":\"2024-12-03T17:08:00+00:00\",\"description\":\"While diffusion pumps are fairly simple to operate, here are 12 things every vacuum furnace user should avoid when using a diffusion pump.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/#primaryimage\",\"url\":\"\",\"contentUrl\":\"\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/12-things-to-avoid-when-using-a-diffusion-pump\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ipsenglobal.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge Center\",\"item\":\"https:\\\/\\\/dipsen.wpengine.com\\\/knowledge-center\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"12 Things to Avoid When Using a Diffusion Pump\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#website\",\"url\":\"https:\\\/\\\/dipsen.wpengine.com\\\/\",\"name\":\"Ipsen Global\",\"description\":\"Strengthening Innovation Worldwide\",\"publisher\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dipsen.wpengine.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\",\"name\":\"Ipsen\",\"url\":\"https:\\\/\\\/dipsen.wpengine.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Ipsen-Pantone186C_Large_W_White.jpg\",\"contentUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Ipsen-Pantone186C_Large_W_White.jpg\",\"width\":1090,\"height\":545,\"caption\":\"Ipsen\"},\"image\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/IpsenUSA\",\"https:\\\/\\\/x.com\\\/ipsenusa\",\"https:\\\/\\\/www.instagram.com\\\/ipsenusa\\\/\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/ipsenvideos\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/person\\\/8fb2c2ce715f8b2c86dd1ab9f3021543\",\"name\":\"Courtney Kerch\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"caption\":\"Courtney Kerch\"},\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/fr\\\/author\\\/ckerch\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"12 choses \u00e0 \u00e9viter lors de l'utilisation d'une pompe \u00e0 diffusion - Ipsen Global","description":"Bien que les pompes \u00e0 diffusion soient relativement simples \u00e0 utiliser, voici 12 choses que tout utilisateur de four \u00e0 vide devrait \u00e9viter lorsqu'il utilise une pompe \u00e0 diffusion.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ipsenglobal.com\/fr\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/","og_locale":"fr_FR","og_type":"article","og_title":"12 Things to Avoid When Using a Diffusion Pump - Ipsen Global","og_description":"While diffusion pumps are fairly simple to operate, here are 12 things every vacuum furnace user should avoid when using a diffusion pump.","og_url":"https:\/\/ipsenglobal.com\/fr\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/","og_site_name":"Ipsen Global","article_publisher":"https:\/\/www.facebook.com\/IpsenUSA","article_modified_time":"2024-12-03T17:08:00+00:00","twitter_card":"summary_large_image","twitter_site":"@ipsenusa","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"TechArticle","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/#article","isPartOf":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/"},"author":{"name":"Courtney Kerch","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/person\/8fb2c2ce715f8b2c86dd1ab9f3021543"},"headline":"12 Things to Avoid When Using a Diffusion Pump","datePublished":"2019-06-11T20:13:46+00:00","dateModified":"2024-12-03T17:08:00+00:00","mainEntityOfPage":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/"},"wordCount":325,"publisher":{"@id":"https:\/\/dipsen.wpengine.com\/#organization"},"image":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/#primaryimage"},"thumbnailUrl":"","keywords":["diffusion pump","vacuum furnace"],"articleSection":["Blog Post","Preventive Maintenance","Pumping Systems"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/","url":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/","name":"12 choses \u00e0 \u00e9viter lors de l'utilisation d'une pompe \u00e0 diffusion - Ipsen Global","isPartOf":{"@id":"https:\/\/dipsen.wpengine.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/#primaryimage"},"image":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/#primaryimage"},"thumbnailUrl":"","datePublished":"2019-06-11T20:13:46+00:00","dateModified":"2024-12-03T17:08:00+00:00","description":"Bien que les pompes \u00e0 diffusion soient relativement simples \u00e0 utiliser, voici 12 choses que tout utilisateur de four \u00e0 vide devrait \u00e9viter lorsqu'il utilise une pompe \u00e0 diffusion.","breadcrumb":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/#primaryimage","url":"","contentUrl":""},{"@type":"BreadcrumbList","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/12-things-to-avoid-when-using-a-diffusion-pump\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ipsenglobal.com\/"},{"@type":"ListItem","position":2,"name":"Knowledge Center","item":"https:\/\/dipsen.wpengine.com\/knowledge-center\/"},{"@type":"ListItem","position":3,"name":"12 Things to Avoid When Using a Diffusion Pump"}]},{"@type":"WebSite","@id":"https:\/\/dipsen.wpengine.com\/#website","url":"https:\/\/dipsen.wpengine.com\/","name":"Ipsen Global","description":"Renforcer l'innovation dans le monde","publisher":{"@id":"https:\/\/dipsen.wpengine.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dipsen.wpengine.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/dipsen.wpengine.com\/#organization","name":"Ipsen","url":"https:\/\/dipsen.wpengine.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/logo\/image\/","url":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/10\/Ipsen-Pantone186C_Large_W_White.jpg","contentUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/10\/Ipsen-Pantone186C_Large_W_White.jpg","width":1090,"height":545,"caption":"Ipsen"},"image":{"@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/IpsenUSA","https:\/\/x.com\/ipsenusa","https:\/\/www.instagram.com\/ipsenusa\/","https:\/\/www.youtube.com\/user\/ipsenvideos"]},{"@type":"Person","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/person\/8fb2c2ce715f8b2c86dd1ab9f3021543","name":"Courtney Kerch","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","caption":"Courtney Kerch"},"url":"https:\/\/ipsenglobal.com\/fr\/author\/ckerch\/"}]}},"taxonomy_info":{"category":[{"value":558,"label":"Blog Post"},{"value":612,"label":"Preventive Maintenance"},{"value":654,"label":"Pumping Systems"}],"post_tag":[{"value":472,"label":"diffusion pump"},{"value":75,"label":"vacuum furnace"}]},"featured_image_src_large":false,"author_info":{"display_name":"Courtney Kerch","author_link":"https:\/\/ipsenglobal.com\/fr\/author\/ckerch\/"},"comment_info":"","_links":{"self":[{"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/wp\/v2\/knowledge-center\/526","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/wp\/v2\/knowledge-center"}],"about":[{"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/wp\/v2\/types\/knowledge-center"}],"author":[{"embeddable":true,"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"version-history":[{"count":1,"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/wp\/v2\/knowledge-center\/526\/revisions"}],"predecessor-version":[{"id":9703,"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/wp\/v2\/knowledge-center\/526\/revisions\/9703"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/"}],"wp:attachment":[{"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/wp\/v2\/media?parent=526"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/wp\/v2\/categories?post=526"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ipsenglobal.com\/fr\/wp-json\/wp\/v2\/tags?post=526"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}