{"id":10397,"date":"2025-02-26T19:38:51","date_gmt":"2025-02-26T19:38:51","guid":{"rendered":"https:\/\/ipsenglobal.com\/?post_type=knowledge-center&#038;p=10397"},"modified":"2026-03-11T17:32:38","modified_gmt":"2026-03-11T17:32:38","slug":"ask-the-expert-dew-point-monitoring-systems","status":"publish","type":"knowledge-center","link":"https:\/\/ipsenglobal.com\/it\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/","title":{"rendered":"Chiedi all'esperto: Sistemi di monitoraggio del punto di rugiada"},"content":{"rendered":"<h4 class=\"wp-block-heading\">Con Craig Moller - ingegnere capo, Brad Stewart - responsabile dell'ingegneria del software e dei controlli e Steve Hartenberger - responsabile del prodotto retrofit elettrico.<\/h4>\n\n\n\n<div style=\"height:29px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Il vapore acqueo \u00e8 ovunque. Anche in una fredda e secca giornata invernale nel nord dell'Illinois, c'\u00e8 vapore acqueo nell'aria. Misuriamo il vapore acqueo ambientale calcolando il punto di rugiada: la temperatura a cui l'aria deve essere raffreddata per raggiungere un'umidit\u00e0 relativa di 100% a una determinata pressione costante.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Quindi, quando la temperatura raggiunge i 10\u00b0 F in pieno inverno e l'esperto meteo locale segnala un punto di rugiada di -7\u00b0 F, significa che, supponendo che le temperature notturne seguano il loro solito andamento e che la pressione atmosferica rimanga costante, possiamo aspettarci che l'acqua precipiti dall'atmosfera. Questo pu\u00f2 portare alla formazione di nebbia o brina sulle superfici fredde se la temperatura scende al di sotto dei -7\u00b0F.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\"-7\u00b0 F sarebbe un punto di rugiada molto negativo per il gas di riempimento\", ha spiegato Craig Moller, ingegnere capo di Ipsen. \"\u00c8 un contenuto d'acqua troppo elevato. Quando monitoriamo gas di processo come l'argon, in genere cerchiamo punti di rugiada tra -60\u00b0 F e -100\u00b0 F\".<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Le alte temperature e le basse pressioni all'interno di un <a href=\"https:\/\/ipsenglobal.com\/it\/vacuum-furnaces\/\">forno a vuoto<\/a> pu\u00f2 scindere le molecole d'acqua nei loro elementi componenti, l'idrogeno e l'ossigeno. Se l'ossigeno viene introdotto in un processo di trattamento termico, pu\u00f2 causare lo scolorimento o l'ossidazione dei pezzi, nonch\u00e9 il danneggiamento della zona calda.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Monitoraggio del punto di rugiada dei gas di processo<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Sensori del punto di rugiada<\/strong> possono svolgere un ruolo importante nel proteggere i forni e i componenti dall'ingresso di vapore acqueo nella camera attraverso perdite nei sistemi di gas di processo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I sensori di punto di rugiada sono tipicamente installati in linea con un gas di processo, come argon o azoto. Il sensore verifica la presenza e la concentrazione di vapore acqueo nel flusso appena prima che il gas di processo entri nella camera a vuoto. Il sensore \u00e8 collegato a un igrometro con display digitale che pu\u00f2 fornire uscite di allarme analogiche, digitali e a doppio rel\u00e8. I sensori del punto di rugiada sono in grado di fornire informazioni accurate finch\u00e9 il gas scorre, sia ad alta pressione che a un lento rivolo. I sensori possono essere impostati per fornire una lettura per l'ispezione manuale o per il monitoraggio attivo attraverso l'integrazione con il PLC e il software di controllo del forno, in modo da registrare le tendenze e generare allarmi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\"Quando si tratta dei nostri clienti del settore aerospaziale, molte delle loro ricette specificano che determinati gas di processo e di tempra devono essere molto puri. Quando ordinano gas di processo come l'argon, quanto pi\u00f9 secco \u00e8 il gas, tanto pi\u00f9 alto \u00e8 il costo\", spiega Brad Stewart, Software and Controls Engineering Lead. \"I clienti del settore aerospaziale sanno che quando utilizzano l'argon per le loro ricette di lavorazione termica, devono rispettare specifici standard di punto di rugiada\".<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p class=\"wp-block-paragraph\">I fornitori di gas industriali possono offrire prodotti che vanno dalla purezza 99% fino alla purezza 99,995%, ma il collegamento di grandi serbatoi di gas all'aperto ai forni a vuoto di un impianto di produzione pu\u00f2 comportare molti metri di tubi. Non \u00e8 raro incontrare molte giunzioni, curve, raccordi e valvole lungo il percorso. Ogni giunzione comporta il rischio di perdite che, anche in presenza di pressione positiva, possono consentire all'aria ambiente (e in particolare al vapore acqueo) di entrare nel sistema e provocare l'ossidazione dei componenti*.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Inoltre, ci sono ricette che possono prevedere l'introduzione di due gas diversi nel forno, come l'argon e l'azoto, ognuno dei quali avrebbe le proprie specifiche sul punto di rugiada. \"La maggior parte dei nostri clienti che utilizzano questi processi sanno di aver bisogno di un sensore del punto di rugiada e chiedono specificamente di includerlo in un nuovo forno o di installarlo in un retrofit\", ha osservato Steve Hartenberger, Product Leader per i retrofit elettrici.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p class=\"has-white-color has-blue-background-color has-text-color has-background has-link-color wp-elements-0eb671d2fe26578aea90989cc1471a26 wp-block-paragraph\" style=\"font-size:16px\"><strong>*<\/strong>Il Principio di Bernoulli dimostra che in un sistema di gas con generazione di pressione direzionale da un tubo grande che si riduce a un tubo pi\u00f9 stretto, la pressione del gas all'interno del tubo stretto sar\u00e0 inferiore a quella del tubo pi\u00f9 grande. Una perdita in una sezione di questo tubo stretto pu\u00f2 agire come un vuoto, attirando i gas ambientali nel sistema.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"76736f\" data-has-transparency=\"false\" style=\"--dominant-color: #76736f;\" loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1.avif\" alt=\"vacuum furnace dew point monitor\" class=\"wp-image-10424 not-transparent\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1.avif 1000w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1-300x300.avif 300w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1-150x150.avif 150w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1-768x768.avif 768w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1-12x12.avif 12w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img data-dominant-color=\"bebcbf\" data-has-transparency=\"false\" style=\"--dominant-color: #bebcbf;\" loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/02\/Dew-Point-3.avif\" alt=\"\" class=\"wp-image-10544 not-transparent\" srcset=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/02\/Dew-Point-3.avif 1000w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/02\/Dew-Point-3-300x300.avif 300w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/02\/Dew-Point-3-150x150.avif 150w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/02\/Dew-Point-3-768x768.avif 768w, https:\/\/ipsenglobal.com\/wp-content\/uploads\/2025\/02\/Dew-Point-3-12x12.avif 12w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Si raccomanda agli operatori con sensori di punto di rugiada in linea di controllare e registrare le letture del punto di rugiada prima di ogni ciclo. I sistemi integrati possono segnalare e registrare le letture del punto di rugiada durante il ciclo. Se una lettura del punto di rugiada non rientra nelle specifiche, il sensore pu\u00f2 essere istruito a far scattare un allarme.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\"Gli allarmi del punto di rugiada possono aiutare gli operatori a identificare una possibile fonte di ossidazione\", ha spiegato Moller. \"Pi\u00f9 alta \u00e8 la velocit\u00e0 del gas che si muove attraverso il tubo, maggiori sono le possibilit\u00e0 di aspirare aria attraverso una perdita e maggiore \u00e8 la probabilit\u00e0 di far scattare l'allarme\".<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Quando un allarme del sistema del punto di rugiada si attiva a met\u00e0 ciclo, l'operatore dovr\u00e0 registrare le letture, la parte del processo in cui \u00e8 scattato l'allarme e consentire il completamento del ciclo, seguito da un'attenta ispezione delle parti e della zona calda.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\"L'allarme di un sensore di punto di rugiada significa che \u00e8 giunto il momento di effettuare un test di bolla sui raccordi\", suggerisce Moller.<\/p>\n\n\n\n<p class=\"has-white-color has-blue-background-color has-text-color has-background has-link-color wp-elements-fe103ee5e0114ab948ef5e727ceb9898 wp-block-paragraph\" style=\"font-size:16px\">Come identificare l'origine di un problema di punto di rugiada:<br>- Eseguire un test a bolle d'aria sulle linee del gas per verificare la presenza di perdite in tutte le giunzioni (giunti, curve, raccordi e valvole).<br>- Verificare che il gas all'interno del serbatoio di stoccaggio sia conforme alle specifiche di purezza.<br>- Dopo aver completato il test delle bolle sulle giunzioni, pompare la linea del forno fino al serbatoio di accumulo del gas ed eseguire un test del vuoto con l'elio.<br>- Se il sensore del punto di rugiada \u00e8 ancora fuori portata, eseguire un altro test della bolla di pressione positiva dal forno alla fonte di gas.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"wp-block-paragraph\">Per ulteriori consigli utili, visitate il nostro&nbsp;<a href=\"https:\/\/ipsenglobal.com\/it\/category\/ask-the-expert\/\" target=\"_blank\" rel=\"noreferrer noopener\">Pagina Chiedi all'esperto<\/a>.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\">Avete una domanda tecnica relativa al trattamento termico o al funzionamento e alla manutenzione dei forni a vuoto?<\/h5>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n    <section id=\"button-block_50f953783a1741246cc040517e8848d3\"\n        class=\"button-custom-block d-block d-lg-inline-block mx-auto me-lg-5 mb-4\">\n        <a class=\"btn btn-outline-secondary\" href=\"https:\/\/ipsenglobal.com\/it\/connect-with-an-expert\/\" target=\"_blank\">\n            Collegatevi con un esperto Ipsen        <\/a>\n    <\/section>","protected":false},"excerpt":{"rendered":"<p>Con Craig Moller - ingegnere capo, Brad Stewart - responsabile dell'ingegneria del software e dei controlli e Steve Hartenberger - responsabile del prodotto retrofit elettrico Il vapore acqueo \u00e8 ovunque. Anche in un ambiente freddo,<\/p>","protected":false},"author":7,"featured_media":0,"menu_order":0,"template":"","meta":{"_acf_changed":false,"_tec_requires_first_save":true,"_searchwp_excluded":"","_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_price":"","_stock":"","_tribe_ticket_header":"","_tribe_default_ticket_provider":"","_tribe_ticket_capacity":"0","_ticket_start_date":"","_ticket_end_date":"","_tribe_ticket_show_description":"","_tribe_ticket_show_not_going":false,"_tribe_ticket_use_global_stock":"","_tribe_ticket_global_stock_level":"","_global_stock_mode":"","_global_stock_cap":"","_tribe_rsvp_for_event":"","_tribe_ticket_going_count":"","_tribe_ticket_not_going_count":"","_tribe_tickets_list":"[]","_tribe_ticket_has_attendee_info_fields":false,"_EventAllDay":false,"_EventTimezone":"","_EventStartDate":"","_EventEndDate":"","_EventStartDateUTC":"","_EventEndDateUTC":"","_EventShowMap":false,"_EventShowMapLink":false,"_EventURL":"","_EventCost":"","_EventCostDescription":"","_EventCurrencySymbol":"","_EventCurrencyCode":"","_EventCurrencyPosition":"","_EventDateTimeSeparator":"","_EventTimeRangeSeparator":"","_EventOrganizerID":[],"_EventVenueID":[],"_OrganizerEmail":"","_OrganizerPhone":"","_OrganizerWebsite":"","_VenueAddress":"","_VenueCity":"","_VenueCountry":"","_VenueProvince":"","_VenueState":"","_VenueZip":"","_VenuePhone":"","_VenueURL":"","_VenueStateProvince":"","_VenueLat":"","_VenueLng":"","_VenueShowMap":false,"_VenueShowMapLink":false,"_tribe_blocks_recurrence_rules":"","_tribe_blocks_recurrence_description":"","_tribe_blocks_recurrence_exclusions":"","_ecp_custom_2":"","footnotes":""},"categories":[112],"tags":[],"class_list":["post-10397","knowledge-center","type-knowledge-center","status-publish","hentry","category-ask-the-expert"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Ask the Expert: Dew Point Monitoring Systems - Ipsen Global<\/title>\n<meta name=\"description\" content=\"Learn about dew point monitoring systems, how they protect vacuum furnaces, and why accurate readings are crucial.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ipsenglobal.com\/it\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ask the Expert: Dew Point Monitoring Systems - Ipsen Global\" \/>\n<meta property=\"og:description\" content=\"Learn about dew point monitoring systems, how they protect vacuum furnaces, and why accurate readings are crucial.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ipsenglobal.com\/it\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/\" \/>\n<meta property=\"og:site_name\" content=\"Ipsen Global\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/IpsenUSA\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-11T17:32:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1.avif\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@ipsenusa\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minuti\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"TechArticle\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/\"},\"author\":{\"name\":\"Courtney Kerch\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/person\\\/8fb2c2ce715f8b2c86dd1ab9f3021543\"},\"headline\":\"Ask the Expert: Dew Point Monitoring Systems\",\"datePublished\":\"2025-02-26T19:38:51+00:00\",\"dateModified\":\"2026-03-11T17:32:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/\"},\"wordCount\":935,\"publisher\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2005\\\/02\\\/DSC_7311_1.avif\",\"articleSection\":[\"Ask the Expert\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/\",\"name\":\"Ask the Expert: Dew Point Monitoring Systems - Ipsen Global\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2005\\\/02\\\/DSC_7311_1.avif\",\"datePublished\":\"2025-02-26T19:38:51+00:00\",\"dateModified\":\"2026-03-11T17:32:38+00:00\",\"description\":\"Learn about dew point monitoring systems, how they protect vacuum furnaces, and why accurate readings are crucial.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2005\\\/02\\\/DSC_7311_1.avif\",\"contentUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2005\\\/02\\\/DSC_7311_1.avif\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ipsenglobal.com\\\/knowledge-center\\\/ask-the-expert-dew-point-monitoring-systems\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/ipsenglobal.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge Center\",\"item\":\"https:\\\/\\\/dipsen.wpengine.com\\\/knowledge-center\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Ask the Expert: Dew Point Monitoring Systems\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#website\",\"url\":\"https:\\\/\\\/dipsen.wpengine.com\\\/\",\"name\":\"Ipsen Global\",\"description\":\"Strengthening Innovation Worldwide\",\"publisher\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/dipsen.wpengine.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#organization\",\"name\":\"Ipsen\",\"url\":\"https:\\\/\\\/dipsen.wpengine.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Ipsen-Pantone186C_Large_W_White.jpg\",\"contentUrl\":\"https:\\\/\\\/ipsenglobal.com\\\/wp-content\\\/uploads\\\/2022\\\/10\\\/Ipsen-Pantone186C_Large_W_White.jpg\",\"width\":1090,\"height\":545,\"caption\":\"Ipsen\"},\"image\":{\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/IpsenUSA\",\"https:\\\/\\\/x.com\\\/ipsenusa\",\"https:\\\/\\\/www.instagram.com\\\/ipsenusa\\\/\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/ipsenvideos\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/dipsen.wpengine.com\\\/#\\\/schema\\\/person\\\/8fb2c2ce715f8b2c86dd1ab9f3021543\",\"name\":\"Courtney Kerch\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g\",\"caption\":\"Courtney Kerch\"},\"url\":\"https:\\\/\\\/ipsenglobal.com\\\/it\\\/author\\\/ckerch\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Chiedi all'esperto: Sistemi di monitoraggio del punto di rugiada - Ipsen Global","description":"Scoprite i sistemi di monitoraggio del punto di rugiada, come proteggono i forni a vuoto e perch\u00e9 le letture accurate sono fondamentali.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ipsenglobal.com\/it\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/","og_locale":"it_IT","og_type":"article","og_title":"Ask the Expert: Dew Point Monitoring Systems - Ipsen Global","og_description":"Learn about dew point monitoring systems, how they protect vacuum furnaces, and why accurate readings are crucial.","og_url":"https:\/\/ipsenglobal.com\/it\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/","og_site_name":"Ipsen Global","article_publisher":"https:\/\/www.facebook.com\/IpsenUSA","article_modified_time":"2026-03-11T17:32:38+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1.avif","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@ipsenusa","twitter_misc":{"Tempo di lettura stimato":"5 minuti"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"TechArticle","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/#article","isPartOf":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/"},"author":{"name":"Courtney Kerch","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/person\/8fb2c2ce715f8b2c86dd1ab9f3021543"},"headline":"Ask the Expert: Dew Point Monitoring Systems","datePublished":"2025-02-26T19:38:51+00:00","dateModified":"2026-03-11T17:32:38+00:00","mainEntityOfPage":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/"},"wordCount":935,"publisher":{"@id":"https:\/\/dipsen.wpengine.com\/#organization"},"image":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/#primaryimage"},"thumbnailUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1.avif","articleSection":["Ask the Expert"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/","url":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/","name":"Chiedi all'esperto: Sistemi di monitoraggio del punto di rugiada - Ipsen Global","isPartOf":{"@id":"https:\/\/dipsen.wpengine.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/#primaryimage"},"image":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/#primaryimage"},"thumbnailUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1.avif","datePublished":"2025-02-26T19:38:51+00:00","dateModified":"2026-03-11T17:32:38+00:00","description":"Scoprite i sistemi di monitoraggio del punto di rugiada, come proteggono i forni a vuoto e perch\u00e9 le letture accurate sono fondamentali.","breadcrumb":{"@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/"]}]},{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/#primaryimage","url":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1.avif","contentUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2005\/02\/DSC_7311_1.avif"},{"@type":"BreadcrumbList","@id":"https:\/\/ipsenglobal.com\/knowledge-center\/ask-the-expert-dew-point-monitoring-systems\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/ipsenglobal.com\/"},{"@type":"ListItem","position":2,"name":"Knowledge Center","item":"https:\/\/dipsen.wpengine.com\/knowledge-center\/"},{"@type":"ListItem","position":3,"name":"Ask the Expert: Dew Point Monitoring Systems"}]},{"@type":"WebSite","@id":"https:\/\/dipsen.wpengine.com\/#website","url":"https:\/\/dipsen.wpengine.com\/","name":"Ipsen Global","description":"Rafforzare l'innovazione in tutto il mondo","publisher":{"@id":"https:\/\/dipsen.wpengine.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/dipsen.wpengine.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/dipsen.wpengine.com\/#organization","name":"Ipsen","url":"https:\/\/dipsen.wpengine.com\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/logo\/image\/","url":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/10\/Ipsen-Pantone186C_Large_W_White.jpg","contentUrl":"https:\/\/ipsenglobal.com\/wp-content\/uploads\/2022\/10\/Ipsen-Pantone186C_Large_W_White.jpg","width":1090,"height":545,"caption":"Ipsen"},"image":{"@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/IpsenUSA","https:\/\/x.com\/ipsenusa","https:\/\/www.instagram.com\/ipsenusa\/","https:\/\/www.youtube.com\/user\/ipsenvideos"]},{"@type":"Person","@id":"https:\/\/dipsen.wpengine.com\/#\/schema\/person\/8fb2c2ce715f8b2c86dd1ab9f3021543","name":"Courtney Kerch","image":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/046e31caea38a69059edfb28090efb5f0af1696fd41381c07821ac786e7ff9c9?s=96&d=mm&r=g","caption":"Courtney Kerch"},"url":"https:\/\/ipsenglobal.com\/it\/author\/ckerch\/"}]}},"taxonomy_info":{"category":[{"value":112,"label":"Ask the Expert"}]},"featured_image_src_large":false,"author_info":{"display_name":"Courtney Kerch","author_link":"https:\/\/ipsenglobal.com\/it\/author\/ckerch\/"},"comment_info":"","_links":{"self":[{"href":"https:\/\/ipsenglobal.com\/it\/wp-json\/wp\/v2\/knowledge-center\/10397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ipsenglobal.com\/it\/wp-json\/wp\/v2\/knowledge-center"}],"about":[{"href":"https:\/\/ipsenglobal.com\/it\/wp-json\/wp\/v2\/types\/knowledge-center"}],"author":[{"embeddable":true,"href":"https:\/\/ipsenglobal.com\/it\/wp-json\/wp\/v2\/users\/7"}],"version-history":[{"count":14,"href":"https:\/\/ipsenglobal.com\/it\/wp-json\/wp\/v2\/knowledge-center\/10397\/revisions"}],"predecessor-version":[{"id":14237,"href":"https:\/\/ipsenglobal.com\/it\/wp-json\/wp\/v2\/knowledge-center\/10397\/revisions\/14237"}],"wp:attachment":[{"href":"https:\/\/ipsenglobal.com\/it\/wp-json\/wp\/v2\/media?parent=10397"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ipsenglobal.com\/it\/wp-json\/wp\/v2\/categories?post=10397"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ipsenglobal.com\/it\/wp-json\/wp\/v2\/tags?post=10397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}